Coagulation
Diamond
The DIAMOND System is a semiautomatic coagulometer,
a high performance analyzer with photo-optical clot detection. It performs, PT, aPTT, Clauss Fibrinogen and TT.
The DIAMOND has a highly sensitive photometer with a light source provided bu a solid state three wave-lenght led emitter at 460nm. 510nm, 630nm which ensure accurate and precise results.
Technical Specification | |
Sample Reagents Reaction Volume Sample Volume Temperature Control Performed Tests Photometer Photometer Accuracy Keyboard Display Interface Barcode Computer Power Requirement Dimension Wheight | 16 Sample at 37° C 2+2 Position at 37° C - 2 Room Temperature From 150ul to 450ul max Minimum 50ul Digital Controlled PT, APTT, TT, FIB and TT Triple Wavelength 450nm - 510nm - 630nm High Linearity +/-0.5% F.S. Alfanumeric Keyboard LCD - Graphic module 128x64 Pixel Bluetooth - Optional Not present Internal 30 mips uPROCESSOR Internal 12 Volt DC power supply H 8cm/3,1inch - W 19cm/7,4inch - L 21cm/8,2inch 1Kg - 2,20Lbs |
Diamond 2
The Diamond 2 is a semiautomatic coagulometer, a high-performance analyzer with photo-optical clot detection.
It performs all coagulation tests. The Diamond 2 has two highly sensitive photometers, with a light source provided by two solid-state three-wavelength emitters (405 nm, 450 nm, 630 nm), ensuring accurate and precise results.
Diamond 4
The Diamond 2 is a semiautomatic coagulometer, a high-performance analyzer with photo-optical clot detection.
It performs all coagulation tests. The Diamond 2 has two highly sensitive photometers, with a light source provided by two solid-state three-wavelength emitters (405 nm, 450 nm, 630 nm), ensuring accurate and precise results.
Technical Specification | |
Sample Reagents Reaction Volume Sample Volume Temperature Control Performed Tests Photometer Photometer Accuracy Keyboard Display Interface Barcode Computer Power Requirement Dimension Wheight | 16 Sample at 37° C 2 + 2 Position at 37° C From 150ul to 450ul max Minimum 50ul Digital Controlled PT. APTT. TT. Fibrinogen, Factors, Protein C and S Triple Wavelength 405nm - 450nm - 630 nm High Linearity +/-0.5% F.S. Touchscreen LCD XGA 800x480 Full Color Bluetooth - Optional 3 Microprocessors12 Volt DC powe supply - Battery Optional H 8cm/3.1inch - W 21cm/8.2inch - L 21cm/8.2inch 1 Kg - 2.20 Lbs Bluetooth - Optional |
Technical Specification | |
Samples Reagents Reaction Volume Sample Volume Temperature Control Performed Tests Photometer Keyboard Display Interface Computer Power Requirement Dimension Wheight Printer LIS Barcode | 15 Sample at 37° C 2 Position at 37° C From 150ul to 450ul max Minimum 50ul Digital Controlled PT. APTT. TT. Fibrinogen, Factors, Protein C and S Triple Wavelengths 450nm - 630nm Touchscreen LCD XGA 7" Capacitive Bluetooth - Optional 5 Microprocessors 12 Volt DC powe supply - Battery Optional H 12cm/4,72inch - W 23cm/9,052inch - L 40cm/15,7inch 5Kg - 1,02Lbs Bluetooth - Optional RS232 - Optional |